Data Centres
Ultra secure, reliable environments
Providing and maintaining data centre space is a specialist business and Highway 1 recognises that business customers require the most reliable and secure environment to deliver 99.99% uptime. Highway 1 only leases space from tier-3 configured data centres with complete environmental and security management.
Full Rack Offer - SYDVR3
$2000 Setup, $1600/mth (ex tax) - 45RU Rack in Sydney Vocus Data Centre (Alexendria), 10Amp Dual A+B Redundant Feeds, 24x7 Unescorted Access (After DC Induction and Swipe Card Payment). Does not include internet services but we can provide a great deal for you!. Minimum contract term of 12 months. Promotional Code: SYDVR3. Email our Business Sales Team or call 1300 139 550 for further information.
Full Rack + 5Mbps Internet Bundle - SYDVR2
$1700 Setup, $1825/mth (ex tax) - 45RU Rack in Sydney Vocus Data Centre (Alexendria), 10Amp Dual A+B Redundant Feeds, 24x7 Unescorted Access (After DC Induction and Swipe Card Payment). 5Mbps FREE Business-Grade Internet Transit (1:8). Minimum contract term of 24 months. Promotional Code: SYDVR2. Email our Business Sales Team or call 1300 139 550 for further information.
1-15RU Colocation
If you want to co-locate 1RU to 15RU in a Highway 1 data centre please see our Colocation Plans.
Full, Half and Third Racks
We specialise in customised rack solutions for businesses with special requirements including:
- Higher power (10KW+) or special delivery (3-Phase power) needs.
- Single Network Multi Data Centre Sites (Replication, DR etc)
- Interconnects to third party carriers and suppliers.
- Mirroring of internal services for distaster recovery.
- Private network links to your equipment (Ethernet, Dark Fibre. E1, Frame Relay).
- Multiple rack services and bundling with other Highway 1 services.
Our Locations
| State | Data Centre | Suburb | Address |
|---|---|---|---|
| New South Wales | Globalswitch | Ultimo | Harris St |
| New South Wales | Vocus | Alexandria | Doody St |
| Queensland | PIPE | Brisbane | Creek St |
| Victoria | PIPE | Port Melbourne | Crockford St |
| Western Australia | Acure | Perth | St Georges Terrace |
| Western Australia | Acure | East Perth | Murchison Terrace |
Sydney (Harris St) Technical Specifications
- 41,575sqm custom built facility
- Minimum N+1 on power supply
- Diverse A&B Power Supply
- Dedicated 24 hour onsite management team
- Restricted swipe card access (24x 7)
- Temperature in Technical Space maintained at 22C
- Up to 7x 4.5MW Redundant chilling units
- 22 Rotary UPS units and onsite diesel tanks with 24hr runtime on full load
- Fibre and CAT5e cabling available
- Cross connections available with Telstra, Optus, PIPE, Macquarie, Primus, AAPT, Verizon, PacNet, Yahoo, Uecomm and many more
- Dedicated Goods Lift (10 Tonne capacity)
- Network uplinks to the core switches are a minimum of 100Mbit.
Sydney (Doody St) Technical Specifications
- 400 sqm custom built facility
- 99.995% Uptime and Concurrently Maintainable
- Rack Size 48RU (600mm W x 900mm D)
- Minimum N+1 or N+N with Battery Reserve up to 15 Minutes
- Redundant A+B Supply Distributed at 415 Busbar
- Dedicated 24 hour onsite management team
- Restricted swipe card access (24x 7)
- Temperature in Technical Space maintained at 22C
- Design Redundant, N+1, Chilled Water Cooling System
- Generator Fuel Capacity 24 Hours Fuel Capacity Onsite with 24x365 Fuel Delivery Callout
- Fibre and CAT6 cabling available
- Cross connections available with Telstra, Optus, PIPE, Primus and many more carriers
- Network uplinks to the core switches are a minimum of 100Mbit.
Perth DC1 (St Georges Terrace) Technical Specifications
- 140sqm located within the CBD (Ex Bank vault)
- "Lights Off" Monitored Facility
- Rack Size 45RU (600mm W x 900mm D)
- All racks have dual independent UPS power circuits
- Restricted swipe card access (24x 7)
- Raised floor for enhanced heat dispersion
- Redundant Liebert PeC/PeX air conditioning units
- Liebert 7200 Series UPS with dedicated dual standby generator (auto start on mains failure) 72 hour runtime on full capacity
- Laser VESDA (Very Early Smoke Detection Apparatus)
- Water Suppression System
- CAT6 cabling throughout
- Cross connections available with Telstra, Optus, NextGen, PIPE, AAPT, Amcom, WAIX and Metromesh
- Dedicated Lift to basement (5 Tonne capacity)
- Environmental Monitoring System
- Network uplinks to the core switches are a minimum of 100Mbit.
Perth DC2 (Murchison Terrace) Technical Specifications
- 320sqm located within the CBD (Ex Bank Clearing House)
- "Lights On" Staffed Operations Centre
- Rack Size 45RU (600mm W x 1070mm D)
- All racks have dual independent UPS power circuits
- Up to 12KW
- Restricted swipe card access (24x 7)
- Raised floor for enhanced heat dispersion
- Diverse A+B power supply distributed by Dual Bus UPS system on A+B lead
- Backup diesel generators with continuous operation capability
- Laser VESDA (Very Early Smoke Detection Apparatus)
- Air Cooled cooling systems: N+1 (optionally N+2)
- Return temperature: 23 deg C (+/-2 deg)
- Humidity Range: 50% (+/- 10%)
- Interior and exterior CCTV cameras
- Parking, Ramp Loading, temporary build and storage facilities
Further Reading
For colocation plans (1-15 RU) please visit our Colocation Plans.
- Our Network Specifications
- Colocation FAQ
How can we help you?
Please call our Business Sales Team on 1300 139 550 to discuss your Data Centre requirements.